| CompanyProductsOrderingResearch ApplicationsNews, Resources & Events |
Rates
& Durations
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ALZET Pump Model |
|||
| Model Numbers |
1003D, 1007D, 1002, 1004 |
2001D, 2001, 2002, 2004, 2006 |
2ML1, 2ML2, 2ML4 |
Reservoir Volume |
100 µl |
200 µl |
2 ml |
| |
![]() |
![]() |
![]() |
Complete Osmotic Pump |
|||
Length (cm) |
1.5 |
3.0 |
5.1 |
Diameter (cm) |
0.6 |
0.7 |
1.4 |
Weight (g) |
0.4 |
1.1 |
5.1 |
Total Displaced Volume (ml) |
0.5 |
1.0 |
6.5 |
Filling Tube |
|||
Length (cm) |
1.1 |
2.2 |
3.5 |
Gauge |
27 |
27 |
25 |
O.D. (cm) |
0.04 |
0.04 |
0.05 |
I.D. (cm) |
0.02 |
0.02 |
0.03 |
Flow Moderator |
|||
Length (cm) |
1.3 |
2.4 |
4.6 |
Gauge |
21 |
21 |
21 |
O.D. (cm) |
0.08 |
0.08 |
0.08 |
I.D. (cm) |
0.05 |
0.05 |
0.05 |
Weight (g) |
0.05 |
0.2 |
0.9 |
Material (flange) |
Styrene Acrylonitrile |
Styrene Acrylonitrile |
Styrene Acrylonitrile |
Material (cap) |
n/a |
Polyethylene |
Polyethylene |
Material (tube) |
Stainless Steel 304 |
Stainless Steel 304 |
Stainless Steel
304 |
Pump Body Materials |
|||
Outer Membrane |
Cellulose Ester Blend |
||
Drug Reservoir |
Thermoplastic Hydrocarbon Elastomer |
||
|
|||
ALZET pumps are supplied in multiples of 10. Every 10 pumps comes with the following:
Flow Moderators |
Filling Tubes |
||||
| 100X pumps |
200X pumps |
2MLX pumps |
100X pumps |
200X pumps |
2MLX pumps |
| #0002602 (white) |
#0002486 (white) |
#0002501 (white) |
#0007988 |
#0007987 |
#0007986 |
#0002609 (blue) |
#0002489 (blue) |
#0002504 (blue) |
|||
| #0002607 (teal) |
#0002488 (teal) |
#0002503 (teal) |
|||
![]() |
![]() |
||||
The Flow Moderator is used with each ALZET pump. It is comprised of a stainless steel tube with a plastic cap and/or flange on one end, depending on the pump model. Its purpose is twofold. The stainless steel tube provides capillary action, which prevents the test solution from leaking out of the pump reservoir. The steel tube also provides a means for attaching a catheter to all models of ALZET pump. (Performing MRI? See alternatives to a metal flow moderator)
The Filling Tube is a blunt-tipped needle that is cut to the appropriate length depending on the size of the pump. It has a hub for attaching to a syringe. (filling procedure) (order filling tubes)

![]()
ALZET Brain Infusion Kit 3Catalog Number: 0008851 Ideal for brain infusion
in mice
|
||
|
|
||
©2008 DURECT Corporation – All Rights Reserved. |